Volume 16 Issue 12
Aug.  2022
Turn off MathJax
Article Contents
ZHANG You-you, TAO Hai-ying, JIN Dou, TU Chuan-fa, YANG Hong-wei, WANG Li-jun. Clinical analysis of blood glucose monitoring by real-time insulin pump system[J]. Chinese Journal of General Practice, 2018, 16(12): 2024-2027. doi: 10.16766/j.cnki.issn.1674-4152.000552
Citation: ZHANG You-you, TAO Hai-ying, JIN Dou, TU Chuan-fa, YANG Hong-wei, WANG Li-jun. Clinical analysis of blood glucose monitoring by real-time insulin pump system[J]. Chinese Journal of General Practice, 2018, 16(12): 2024-2027. doi: 10.16766/j.cnki.issn.1674-4152.000552

Clinical analysis of blood glucose monitoring by real-time insulin pump system

doi: 10.16766/j.cnki.issn.1674-4152.000552
  • Received Date: 2018-06-16
    Available Online: 2022-08-06
  • Objective To investigate the effect of real-time dynamic insulin pump on blood glucose monitoring in patients with type 2 diabetes mellitus. Methods From January, 2013 to December, 2016, 210 patients with type 2 diabetes were selected as the subjects. All the patients were divided into observation group (152 cases, Medtronic monitoring blood sugar) and control group (58 cases, blood sugar was monitored by traditional method). The indicator for further observation included the blood glucose data of patients monitored by different monitoring methods; the monitoring of blood glucose by Medtronic on first days and third days, the tolerance of patients during monitoring blood glucose. Results During the monitoring of blood glucose, the blood sugar changes in the two groups were all controlled, and the dynamic blood glucose curve showed that the blood glucose data value gradually stabilized. The time of blood glucose reaching the standard in the observation group was (3.52±1.40)days and that in the control group was (6.03±1.51) days. The difference between the two groups was significant (t=10.985, P<0.05). The area under the blood glucose curve of observation group was (88.43±11.15) and that of control group was (99.48±15.26). The difference between the two groups was statistically significant (t=5.026, P<0.001). While the observation group found that 4 patients had low blood sugar in the next morning and adjusted the insulin dosage accordingly. The number of hyperglycemia monitoring for third days was (25.60±15.88) times, compared with first days (40.33±25.17) decreased significantly (t=6.102, P<0.001). The Medtronic insulin pump was well tolerated in the observation group, while in the control group, 70.69% patients (41/58) were found in the subcutaneous of insulin infusion, and there were 3 cases in the control group. Conclusion Medtronic can monitor the blood glucose level of type 2 diabetic patients in real time and realize the function of insulin infusion in the islet pump. The immediate monitoring of the continuous 72 h of the blood glucose level in the patients can help to find the early warning of hyperglycemia and the real time fluctuation of blood sugar so as to facilitate the clinical treatment and adjust timely the insulin regimen and dosage during the monitoring period of the blood sugar.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (297) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return